Jump to: navigation, search

Difference between revisions of "HowTo:Create a new MetaProperty"


(VALUE TYPE)
(VALUE TYPE)
 
(2 intermediate revisions by 2 users not shown)
Line 7: Line 7:
 
# It is recommenmded to set at least the description and namespace
 
# It is recommenmded to set at least the description and namespace
 
# Save the changes with {{key press|Ctrl|S}} or the save command
 
# Save the changes with {{key press|Ctrl|S}} or the save command
 +
 +
===VALUE TYPE===
 +
{{Version/WinXSince|4.7.0}}  Since Version 4.7 we support the possibility to define the value type of a property.
 +
 +
With this property, the customizer can control how the property is displayed on the client.
 +
 +
Possible values are:
 +
* Standard (default)
 +
* MinNormMax (supported for string, double and int properties)
 +
* MinMax (supported for string, double and int properties)
 +
 +
[[Category:How-To|Create a new MetaProperty]]
 +
[[Category:Studio|Create a new MetaProperty]]
  
 
== Optional Attributes ==
 
== Optional Attributes ==
Line 64: Line 77:
 
* selecting the desired validation object from the dialog appearing after double-clicking the cell
 
* selecting the desired validation object from the dialog appearing after double-clicking the cell
  
===VALUE TYPE===
 
Start Version 4.7 we support to define value type for special cases. It is a dropdown table, which contain:
 
* Standard (as default)
 
* MinNormMax
 
* MinMax
 
for selecting. The setting is only for system types: string, double, int valid.
 
  
[[Category:How-To|Create a new MetaProperty]]
+
 
[[Category:Studio|Create a new MetaProperty]]
+
 
 +
 
 +
 
  
 
==See also==
 
==See also==

Latest revision as of 16:32, 1 February 2024

Creation of a new MetaProperty

A new MetaProperty has to be created as an instance from CUSTOMMETAPROPERTY using the Bulk Editor control

  1. Navigate to the MetaClass CUSTOMMETAPROPERTY
  2. Create a new instance of CUSTOMMETACLASS by entering a name
  3. Set the data type for the property
    Create new MetaProperty
  4. It is recommenmded to set at least the description and namespace
  5. Save the changes with Ctrl+S or the save command

VALUE TYPE

Since Version 4.7 we support the possibility to define the value type of a property.

With this property, the customizer can control how the property is displayed on the client.

Possible values are:

  • Standard (default)
  • MinNormMax (supported for string, double and int properties)
  • MinMax (supported for string, double and int properties)

Optional Attributes

REFERENCE

Assign a reference
Assign a reference

Assign a reference if the value of the property should link to an UBIK® object. The data type of the MetaProperty has to be Guid that the data (guid) can hold a reference to an UBIK® object.

  1. Locate an existing or create a new Reference
  2. Assign the reference to the REFERENCE property either by
    • dragging and dropping the reference object onto the cell
    • selecting the desired reference from the dialog appearing after double-clicking the cell

SELECTIVELIST

Assign a selective list
Assign a selective list

Assign a selective list to a property, if the respective column should display a Combobox with all items of the list instead of the value field. The value can then only be selected from the list, but not be edited manually anymore.

  1. Locate an existing or create a new Selective List
  2. Assign the list to the SELECTIVELIST property either by
    • dragging and dropping the list object onto the cell
    • selecting the desired list from the dialog appearing after double-clicking the cell

UNITITEM

Set a unit item
Set a unit item

If the property should consider a Unit (for example Ampere, Volt, etc.) the underlying MetaProperty has to incorporate a Unit Item either by

  • dragging and dropping the unit item object onto the cell
  • selecting the desired unit item from the dialog appearing after double-clicking the cell
IC Hint square.pngOnly properties of type Double can posses measuring units!

FORMAT

INDEXCOUNT

Set the number of named index keys, for example to 4.

INDEXKEYS

Enter the index keys as a comma separated list of strings, for example "a,b,c,d" (INDEXCOUNT = 4).

DEFAULTVALUE

Set up to 10 default value(s) for the MetaProperty.

INITIALVALUE

Set up to 10 initial value(s) for the MetaProperty.

CATEGORY

Change category
Change category

If desired change the category of the MetaProperty to a value of the list. The property will then be moved to a new tab if the object is viewed in the View Test Environment or using the Object Editor.

NEEDSVALIDATION

Enable validation by checking the NEEDSVALIDATION attribute of the MetaProperty and let the system explicitely store a validation time stamp information in the database. This is particularly used on the mobile client in combination with the SYSCLS TASK and SYSCLS MEASUREMENTTASK classification.

IC Attention.png'NEEDSVALIDATION' is replaced by UBIK Attribute technique since Version 2.5!

Learn more about UBIK Attributes.

VALUEVALIDATION

Assign a value validation object to the VALUEVALIDATION attribute of the MetaProperty either by

  • dragging and dropping the validation object onto the cell
  • selecting the desired validation object from the dialog appearing after double-clicking the cell




See also