SubSystem Assignment
Contents
Object Linkages
- WorkOrder: Can link to a SubSystem, Equipment, or FunctionalLocation.
- Equipment: Can link to FunctionalLocation and/or SubSystem.
- FunctionalLocation: Can link to a SubSystem.
SubSystem Assignment Priorities
Equipment SubSystem
- FunctionalLocation (Highest Priority): If an Equipment is linked to a FunctionalLocation, its SubSystem is automatically set to match the FunctionalLocation. Manual changes are not allowed.
- Equipment (Default): If no FunctionalLocation is linked, the SubSystem can be set manually on the Equipment.
WorkOrder SubSystem
- FunctionalLocation (Highest Priority): If a WorkOrder is linked to a FunctionalLocation, the SubSystem is set to the FunctionalLocation. Manual changes are not allowed.
- Equipment (Second Priority): If no FunctionalLocation is linked, but an Equipment is linked, the WorkOrder’s SubSystem is set to the Equipment. Manual changes are not allowed.
- WorkOrder (Default): If no FunctionalLocation or Equipment is linked, the SubSystem can be set manually on the WorkOrder.
Update Conditions
- FunctionalLocation SubSystem Changes: Update all linked WorkOrders and Equipments to match.
- Equipment SubSystem Changes (if no FunctionalLocation linked): Update linked WorkOrders to match the Equipment.