Implementing Live Values

Revision as of 07:44, 20 October 2017 by CRO (Talk | contribs) (Created page with "==Implementing Live Values in {{UBIK}} Studio== First of all, download the UBIK.Interface.Module.OPCUA from the ''Augmensys Realease Portal/Plugins'' and copy them into the i...")

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Implementing Live Values in UBIK® Studio

First of all, download the UBIK.Interface.Module.OPCUA from the Augmensys Realease Portal/Plugins and copy them into the injections folder from your UBIK® Studio as well as in the injection folder of the Web Service.

  1. Implementing the Server under System/System.Interface/System.Interface.OPCIUA/OPC_SERVER OPC.
  2. Implementing a Datapoint under System/System.Interface/System.Interface.OPCIUA/OPC_DATAPOINT OPC. As REF_OPC_SERVER take the server created before in step 1.
  3. Create a LiveValue MetaProperty under System/System.Interface/System.Interface.LiveValue/LiveValue_METAPROPERTY and add it to the Metaclass where you want to have the live Values to bee shown.
  4. Add the created Datapoint from Step 2 and add it to an equipment to which it concerns.


This video shows an example of how to add live values to an object and display it on the client.