Difference between revisions of "Activity:ConfigureOpcUa...Item (Activity)"
(→See also) |
|||
Line 10: | Line 10: | ||
}} | }} | ||
− | The ConfigureOPCUAVariable registers a single variable within an [[CreateOPCUAConnection (Activity)|OPC UA Connection]]. Only registered variables can be accessed later on with [[AccessOPCUAVariable (Activity)|AccessOPCUAVariable]] activities. | + | The ConfigureOPCUAVariable registers a single variable within an [[Activity:CreateOPCUAConnection (Activity)|OPC UA Connection]]. Only registered variables can be accessed later on with [[Activity:AccessOPCUAVariable (Activity)|AccessOPCUAVariable]] activities. |
==Arguments== | ==Arguments== | ||
Line 32: | Line 32: | ||
==Usage== | ==Usage== | ||
− | This activity is used to configure a single variable for later access within an [[CreateOPCUAScope (Activity)|OPC scope]], only configured variables will be accessible. | + | This activity is used to configure a single variable for later access within an [[Activity:CreateOPCUAScope (Activity)|OPC scope]], only configured variables will be accessible. |
==Example== | ==Example== |
Revision as of 11:46, 23 February 2015
Configure OPC UA Variable | |
---|---|
Name | ConfigureOPCUAVariable |
Purpose | Configure a single OPC UA variable |
Category | UBIK OPC UA Interface |
Returns | True if successful |
Version | 2.4.1+ |
The ConfigureOPCUAVariable registers a single variable within an OPC UA Connection. Only registered variables can be accessed later on with AccessOPCUAVariable activities.
Contents
Arguments
Argument | Type | Direction | Purpose |
---|---|---|---|
BrowsePath | String | In | Specifies the browse path of the item on the server e.g. "/2:Plant1/2:Machine1/2:Unit1/2:Sensor1"). For a more detailed descriptions please refer to the OPC UA specification. |
AutoRead | Boolean | In | Specifies the variable to be read from the server automatically after a connection to the server has been established. |
Subscribe | Boolean | In | Specifies that the variable should automatically be entered into a subscription with the server to be updated with any changes to its value. |
Interval | TimeSpan | In | Specifies the publishing interval to be used for the subscription. All variables using the same publishing interval are grouped together in a subscription for each publishing interval. |
IndexRange | OpcUaIndexRange | In | For arrays, specifies the index range to be read or written. If left null, the entire array will be transferred. |
Result | Boolean | Out | True if successful, false if failed |
Usage
This activity is used to configure a single variable for later access within an OPC scope, only configured variables will be accessible.
Example
The ConfigureOPCUAVariable activity, as used in the larger example "Read value from OPC variable":