Jump to: navigation, search

Difference between revisions of "Configure Comos for CUI"


Line 1: Line 1:
 
[[File:Wiki_Under_Construction_Start.PNG|1000px]]<noinclude>
 
[[File:Wiki_Under_Construction_Start.PNG|1000px]]<noinclude>
  
−
To run or extend the Comos – {{UBIK}} – Interface => CUI you must do some settings on {{Comos}} side or at least get some data for configuration from {{Comos}}.
+
To run or extend the {{COMOS}} – {{UBIK}} – Interface => CUI you must make some settings on the {{COMOS}} side or at least get some data for configuration from {{COMOS}}.
−
Because {{Comos}} is not a Product from Augmensys, please request all {{Comos}} changes or adaptions at your local Siemens or Siemens Partner.
+
Because {{COMOS}} is not a Product from Augmensys, please request all {{COMOS}} changes or adaptations at your local Siemens or Siemens Partner.
  
 
<!-- DO NOT REMOVE THIS -->{{Template:HowTo/Begin}}<!-- DO NOT REMOVE THIS -->
 
<!-- DO NOT REMOVE THIS -->{{Template:HowTo/Begin}}<!-- DO NOT REMOVE THIS -->
Line 8: Line 8:
 
= Idea and Concept =
 
= Idea and Concept =
 
<!-- DO NOT MODIFY THE NAME OF THIS SECTION, BUT REMOVE IT IF NOT REQUIRED -->
 
<!-- DO NOT MODIFY THE NAME OF THIS SECTION, BUT REMOVE IT IF NOT REQUIRED -->
−
The interfacing of data depends on 3 Parts
+
The interfacing of data depends on three parts
  
−
* the possible representation of data from {{Comos}}
+
* the possible representation of data from {{COMOS}}
−
* the transfer media, like *.xml file or REST API Interface
+
* the transfer mechanisms, like *.xml file or REST API INTERFACE
 
* the processing of the given information in {{UBIK}}
 
* the processing of the given information in {{UBIK}}
  
−
To hand over the primary needed information from {{Comos}} to {{UBIK}} there are only *.xml files to use, cause the {{Comos}} side is writing a the data to a fixed *.xml scheme witch {{UBIK}} is able to read in.
+
To hand over the primary needed information from {{COMOS}} to {{UBIK}} there are only *.xml files to use, because the {{COMOS}} side is writing a the data to a fixed *.xml scheme witch {{UBIK}} is able to read in.
−
This is called Metadata transfer, and hands over data about CDevices, Attributes, StandardTables, PhysicalUnits, and DocumentTypes form Comos to a .xml file.
+
This is called Metadata transfer, and transfers data about CDevices, Attributes, StandardTables, PhysicalUnits, and DocumentTypes from Comos to a .xml file.
−
When {{UBIK}} SmartStudio is importing this, it will generate ComosMetaProxy's with Traget MetaClasse's, ComosMetaProxyProperty's with Target MetaProperty's, SelectiveLists and SelectiveItems, SIUnits and UnitItems, and some ComosDocumentTypeProxy's.
+
When {{UBIK}} SmartStudio imports this, it will generate ComosMetaProxy's with target MetaClasse's, ComosMetaProxyProperty's with target MetaProperty's, SelectiveLists and SelectiveItems, SIUnits and UnitItems, and some ComosDocumentTypeProxy's.
−
For detailed information's about the {{UBIK}} Metaclasses please see
+
For detailed information about the {{UBIK}} MetaClass please see
  
 
* [[MetaProxy]]
 
* [[MetaProxy]]
Line 28: Line 28:
 
<!-- DO NOT MODIFY THE NAME OF THIS SECTION, BUT REMOVE IT IF NOT REQUIRED -->
 
<!-- DO NOT MODIFY THE NAME OF THIS SECTION, BUT REMOVE IT IF NOT REQUIRED -->
  
−
For connection between Comos® and UBIK® via REST API please make sure that Comos-WEB is installed and the License called “COMOS_Mobile_Worker_Server” is available on Comos®.
+
For connection between {{COMOS}} and {{UBIK}} via REST API please make sure that COMOS Web is installed and the license called “COMOS_Mobile_Worker_Server” is available on {{COMOS}}.
  
−
Comos-WEB will need The ComosEvents, ComosGatewayServices and the ComosWebStartPage.
+
COMOS Web will need the Web services:  ComosEvents, ComosGatewayServices and the ComosWebStartPage.
  
 
[[File:Screenshot 2026-08-13 091304.png]]
 
[[File:Screenshot 2026-08-13 091304.png]]
  
−
In the Comos® project settings in the section: "Mobile Solutions" you have to care about that URL to you ComosWebStartPage (including port) is set and also the Comos-Web database key is set.
+
In the {{COMOS}} project settings in the section: "Mobile Solutions" you have ensure that the URL to your ComosWebStartPage (including port) is configured and that the COMOS Web database key is also configured.
  
 
[[File:Screenshot 2026-08-13 093803.png]]
 
[[File:Screenshot 2026-08-13 093803.png]]
  
−
NOTE: on One Domain the database key has to be Unique!
+
NOTE: within one domain the database key must be unique!
  
−
Also in the project settings in the section: "COMOS Mobile Worker Interface" you will find the setting and the values for the active "Comos Project" and if the "Workinglayer" key is empty the released area is connected if not one Workinglayer per project can be connected to UBIK®.
+
Also in the project settings in the section: "COMOS Mobile Worker Interface" you will find the settings and the values for the active "Comos Project" and if the "Workinglayer" key is empty the released area is connected if not one Workinglayer per project can be connected to UBIK®.
  
 
[[File:Screenshot 2026-08-13 094922.png|1000px]]
 
[[File:Screenshot 2026-08-13 094922.png|1000px]]
Line 54: Line 54:
 
<!-- DO NOT MODIFY THE NAME OF THIS SECTION, BUT REMOVE IT IF NOT REQUIRED -->
 
<!-- DO NOT MODIFY THE NAME OF THIS SECTION, BUT REMOVE IT IF NOT REQUIRED -->
  
−
For more detailed information please check you Comos® documentation for "Guide COMOS Mobile Worker"
+
For more detailed information please check you {{COMOS}} documentation for "Guide COMOS Mobile Worker"
  
 
or ask Siemens: [https://www.siemens.com/en-us/products/comos/mobile-worker/ comos-mobile-worker]
 
or ask Siemens: [https://www.siemens.com/en-us/products/comos/mobile-worker/ comos-mobile-worker]

Revision as of 12:08, 31 August 2026

Wiki Under Construction Start.PNG

To run or extend the COMOS® – UBIK® – Interface => CUI you must make some settings on the COMOS® side or at least get some data for configuration from COMOS®. Because COMOS® is not a Product from Augmensys, please request all COMOS® changes or adaptations at your local Siemens or Siemens Partner.


[edit]

Idea and Concept

The interfacing of data depends on three parts

  • the possible representation of data from COMOS®
  • the transfer mechanisms, like *.xml file or REST API INTERFACE
  • the processing of the given information in UBIK®

To hand over the primary needed information from COMOS® to UBIK® there are only *.xml files to use, because the COMOS® side is writing a the data to a fixed *.xml scheme witch UBIK® is able to read in. This is called Metadata transfer, and transfers data about CDevices, Attributes, StandardTables, PhysicalUnits, and DocumentTypes from Comos to a .xml file. When UBIK® SmartStudio imports this, it will generate ComosMetaProxy's with target MetaClasse's, ComosMetaProxyProperty's with target MetaProperty's, SelectiveLists and SelectiveItems, SIUnits and UnitItems, and some ComosDocumentTypeProxy's. For detailed information about the UBIK® MetaClass please see

Comos

For connection between COMOS® and UBIK® via REST API please make sure that COMOS Web is installed and the license called “COMOS_Mobile_Worker_Server” is available on COMOS®.

COMOS Web will need the Web services: ComosEvents, ComosGatewayServices and the ComosWebStartPage.

Screenshot 2026-08-13 091304.png

In the COMOS® project settings in the section: "Mobile Solutions" you have ensure that the URL to your ComosWebStartPage (including port) is configured and that the COMOS Web database key is also configured.

Screenshot 2026-08-13 093803.png

NOTE: within one domain the database key must be unique!

Also in the project settings in the section: "COMOS Mobile Worker Interface" you will find the settings and the values for the active "Comos Project" and if the "Workinglayer" key is empty the released area is connected if not one Workinglayer per project can be connected to UBIK®.

Screenshot 2026-08-13 094922.png

See also

For more detailed information please check you COMOS® documentation for "Guide COMOS Mobile Worker"

or ask Siemens: comos-mobile-worker