Camera calibration needs to be done once per device model, for features requiring depth estimation (e.g. [[AR-Marker|AR-Markers]]). Currently the following device models are calibrated:
+
Camera calibration needs to be done once per device model, for features requiring depth estimation (e.g. [[AR-Marker|AR-Markers]]).  
 +
 
 +
<tabs>
 +
<tab name="Prior to UBIK 4">
 +
Currently the following device models are pre-calibrated:
  
 
{| class="wikitable" | width = "25%" style="text-align: center;"
 
{| class="wikitable" | width = "25%" style="text-align: center;"
Line 10: Line 14:
 
|-
 
|-
 
| HTC One m7 || Android
 
| HTC One m7 || Android
 +
|-
 +
| Dell Latitude E5530 non-vPro || Windows
 +
|-
 +
| Dell Inc. Latitude 5591 || Windows
 +
|-
 +
| Durabook R11AH || Windows
 +
|-
 +
| Microsoft Corporation Surface Pro 4 || Windows
 +
|-
 +
| Hewlett-Packard HP Pro Tablet 408 G1 || Windows
 
|-
 
|-
 
|}
 
|}
Line 17: Line 31:
 
== Calibration Procedure ==
 
== Calibration Procedure ==
  
    1. Download and the camera calibration application from the release portal (link)
+
[[File:CameraCalibrationScreenshot.png|thumb|Camera Calibration Application (WinX)]]
    2. Print the asymmetrical circle calibration pattern from the release portal (link).
+
[[File:CameraCalibrationResultScreenshot.png|thumb|Camera Calibration Result (WinX)]]
    3. Verify the correct size by measuring the reference length on the upper right corner.
+
 
    4. Mount the calibration pattern on a planar surface.
+
* Download the camera calibration application from the release portal.
    5. Install and open the Camera Calibration application.
+
* Download and print the [[:File:AsymetricCalibrationPattern.pdf|asymmetrical circle calibration pattern]].
    6. Target the calibration pattern with the camera (the pattern gets augmented -->  
+
* Verify the correct size by measuring the reference length on the upper right corner.
                check if the augmentation is placed at the center of the circles before taking a calibration screenshot).
+
* Mount the calibration pattern on a planar surface.
    7. Tap on the display to mark a frame for calibration.
+
* Install and open the Camera Calibration application.
            a. The calibration pattern should take up aus much of the camera view as possible.
+
* Target the calibration pattern with the camera (the pattern gets augmented --> check if the augmentation is placed at the center of the circles before taking a calibration screenshot).
            b. Keep the camera and calibration pattern stable to not introduce blur.
+
* Tap on the display to mark a frame for calibration. (Press the Capture Button on the WinX client)
            c. Take calibration frames from different viewpoints.
+
** The calibration pattern should take up as much of the camera view as possible.
            d. Circles of the calibration pattern should also be in the corners of the camera view.
+
** Keep the camera and calibration pattern stable to not introduce blur.
            e. Take as much calibration frames as possible (at least 30).
+
** Take calibration frames from different viewpoints.
    8. After having enough calibration frames, open the menu and press calibra-tion.
+
** Circles of the calibration pattern should also be in the corners of the camera view.
    9. A toast indicates that calibration was done and shows the reprojection er-ror. This error should be as low as possible (lower than 3).
+
** Take as many calibration frames as possible (at least 30).
 +
* After having enough calibration frames, open the menu and press calibration (Press Calibrate on the WinX client).
 +
* On Android a toast indicates that calibration was done and shows the reprojection error. This error should be as low as possible (lower than 3). On the WinX client the result section can be expanded.
 +
* The camera matrix and distortion coefficients are now saved on the device in the Downloads folder (in the LocalState folder on the WinX client). The device name is used as the filename of the textfile, on WinX the filename is ''CalibrationResult.txt''
 +
* Forward the calibration file to the development department.
 +
</tab>
 +
 
 +
<tab name=" UBIK 4">
 +
 
 +
[[File:CamCal Settings.jpg|thumb|220px|Camera Calibration in AR Settings]]
 +
 
 +
 
 +
 
 +
 
 +
 
 +
 
 +
From UBIK 4 onwards, the camera calibration can be done directly on the device. Navigate to Settings -> AR and locate the section ''Camera Calibration''. Right of it there are 3 buttons:
 +
 
 +
== Start calibration (Camera symbol {{key press|Android}} {{key press|iOS}}) ==
 +
 
 +
[[File:CamCal Checkerboard.jpg|thumb|220px|Calibration in progress]]
 +
[[File:CamCal Result.jpg|thumb|220px|Calibration result]]
 +
* Download and print the [[:File:AsymetricCalibrationPattern.pdf|asymmetrical circle calibration pattern]].
 +
* Verify the correct size by measuring the reference length on the upper right corner.
 +
* Mount the calibration pattern on a planar surface.
 +
* Target the calibration pattern with the camera (the pattern gets augmented --> check if the augmentation is placed at the center of the circles before taking a calibration screenshot).
 +
* Tap on ''Add Frame'' to mark a frame for calibration.
 +
** The calibration pattern should take up as much of the camera view as possible.
 +
** Keep the camera and calibration pattern stable to not introduce blur.
 +
** Take calibration frames from different viewpoints.
 +
** Circles of the calibration pattern should also be in the corners of the camera view.
 +
** Take as many calibration frames as possible (at least 10).
 +
* After having enough calibration frames, the ''Calibrate'' button will be enabled.
 +
** Once pressed, the result of the calibration is shown on screen.
 +
** Press "Save" to store the camera matrix and distortion coefficients on the device
 +
** Press "Restart" to start a fresh calibration.
 +
 
 +
Return to the settings screen. You will now see text stating ''Device calibrated as [model]'' underneath the ''Camera Calibration'' label. Your device was successfully calibrated.
 +
 
 +
== Export calibration (Download symbol {{key press|Android}} {{key press|iOS}}) ==
 +
Exports the currently stored calibration of this device into a text file, that can be used for import on other devices of the same model. The resulting file will be presented in a share dialog.
 +
 
 +
== Import calibration (Upload symbol {{key press|UWP}}) ==
 +
The native UWP client does not have the built in camera calibration feature, but it can import calibration files that were previously generated and exported from other clients.
 +
 
 +
== Delete calibration (Trash bin symbol) ==
 +
Deletes the currently stored calibration from this device. If no calibration values are stored, the system will use fallback values that are device-agnostic.
 +
 
 +
</tab>
 +
</tabs>

Latest revision as of 16:42, 24 February 2022

Camera calibration needs to be done once per device model, for features requiring depth estimation (e.g. AR-Markers).

Prior to UBIK 4

Currently the following device models are pre-calibrated:

Device Model Operating System
Getac Z710 Android
Sony SGP611 Android
HTC One m7 Android
Dell Latitude E5530 non-vPro Windows
Dell Inc. Latitude 5591 Windows
Durabook R11AH Windows
Microsoft Corporation Surface Pro 4 Windows
Hewlett-Packard HP Pro Tablet 408 G1 Windows

If your device is not yet calibrated, contact the development department. If calibration can´t be done by the development department follow the steps outlined in the following section.

Calibration Procedure

Camera Calibration Application (WinX)
Camera Calibration Result (WinX)
  • Download the camera calibration application from the release portal.
  • Download and print the asymmetrical circle calibration pattern.
  • Verify the correct size by measuring the reference length on the upper right corner.
  • Mount the calibration pattern on a planar surface.
  • Install and open the Camera Calibration application.
  • Target the calibration pattern with the camera (the pattern gets augmented --> check if the augmentation is placed at the center of the circles before taking a calibration screenshot).
  • Tap on the display to mark a frame for calibration. (Press the Capture Button on the WinX client)
    • The calibration pattern should take up as much of the camera view as possible.
    • Keep the camera and calibration pattern stable to not introduce blur.
    • Take calibration frames from different viewpoints.
    • Circles of the calibration pattern should also be in the corners of the camera view.
    • Take as many calibration frames as possible (at least 30).
  • After having enough calibration frames, open the menu and press calibration (Press Calibrate on the WinX client).
  • On Android a toast indicates that calibration was done and shows the reprojection error. This error should be as low as possible (lower than 3). On the WinX client the result section can be expanded.
  • The camera matrix and distortion coefficients are now saved on the device in the Downloads folder (in the LocalState folder on the WinX client). The device name is used as the filename of the textfile, on WinX the filename is CalibrationResult.txt
  • Forward the calibration file to the development department.

UBIK 4

Camera Calibration in AR Settings




From UBIK 4 onwards, the camera calibration can be done directly on the device. Navigate to Settings -> AR and locate the section Camera Calibration. Right of it there are 3 buttons:

Start calibration (Camera symbol Android iOS)

Calibration in progress
Calibration result
  • Download and print the asymmetrical circle calibration pattern.
  • Verify the correct size by measuring the reference length on the upper right corner.
  • Mount the calibration pattern on a planar surface.
  • Target the calibration pattern with the camera (the pattern gets augmented --> check if the augmentation is placed at the center of the circles before taking a calibration screenshot).
  • Tap on Add Frame to mark a frame for calibration.
    • The calibration pattern should take up as much of the camera view as possible.
    • Keep the camera and calibration pattern stable to not introduce blur.
    • Take calibration frames from different viewpoints.
    • Circles of the calibration pattern should also be in the corners of the camera view.
    • Take as many calibration frames as possible (at least 10).
  • After having enough calibration frames, the Calibrate button will be enabled.
    • Once pressed, the result of the calibration is shown on screen.
    • Press "Save" to store the camera matrix and distortion coefficients on the device
    • Press "Restart" to start a fresh calibration.

Return to the settings screen. You will now see text stating Device calibrated as [model] underneath the Camera Calibration label. Your device was successfully calibrated.

Export calibration (Download symbol Android iOS)

Exports the currently stored calibration of this device into a text file, that can be used for import on other devices of the same model. The resulting file will be presented in a share dialog.

Import calibration (Upload symbol UWP)

The native UWP client does not have the built in camera calibration feature, but it can import calibration files that were previously generated and exported from other clients.

Delete calibration (Trash bin symbol)

Deletes the currently stored calibration from this device. If no calibration values are stored, the system will use fallback values that are device-agnostic.